Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Clin Med ; 13(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38610743

RESUMO

Background: The introduction of endovascular thrombectomy dramatically changed acute stroke management and became the standard treatment. Balloon guide catheters provide flow arrest during the clot retrieval process and have several advantages.This study aimed to compare balloon guide catheters (BGCs) versus non-balloon guide catheters (NBGCs) as a part of a combined treatment modality in patients presenting with acute ischemic stroke. Methods: This retrospective study included n = 65 patients who underwent a combined endovascular stroke treatment for distal internal carotid artery (ICA) occlusion. Patients underwent aspiration and stent retriever thrombectomy with the use of BGCs (Group 1, n = 27) or NBGCs (Group 2, n = 38). Results: The groups were compared for outcomes: the National Institutes of Health Stroke Scale (NIHSSS) score change, successful recanalization, good functional outcome at three months, and in-hospital mortality. Conclusion: The two groups didn't differ in terms of the NIHSS score change compared to baseline (p > 0.05). Moreover, there were no significant differences between the two groups in terms of the successful recanalization rate, three-month favorable functional outcome rate, and in-hospital mortality (p = 0.292, p = 0.952, p = 0.178), respectively. Further prospective studies with a larger number of patients and better methodology are warranted.

2.
Eur J Gastroenterol Hepatol ; 33(6): 926-931, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33731592

RESUMO

OBJECTIVE: Transarterial radioembolisation (TARE) is a promising technique for unresectable primary tumours of the liver. We present our clinical experience and the response to treatment and survival data of patients with hepatocellular carcinoma (HCC) who were treated with Y-90 radioembolisation in our hospital's angiography department. MATERIAL AND METHODS: The data of all the patients with HCC referred to our department for Y-90 treatment were analysed retrospectively. The patients were selected according to the treatment protocol criteria, and lung shunt fraction was evaluated using macroaggregated albumin scintigraphy before radioembolisation. Patients with compatible blood tests and lung shunt fraction rates were chosen for treatment with Y-90 TARE. RESULTS: Twenty-four patients were suitable for Y-90 treatment. The patients were treated with 137 ± 44.6 (80-245) Gy Y-90 glass microspheres. The treatment results were evaluated using modified RECIST criteria, and the partial response, complete response, stable disease and progression rates were found to be 54.2, 16.7, 20.8 and 8.3%, respectively. The median survival rate following treatment was 10 months. Higher alpha-fetoprotein (AFP) levels were related to decreased survival, and posttreatment AFP levels had a significant effect on mortality rates. Higher survival rates were detected in the patients who were treated more selectively than the group treated via a lobar approach. CONCLUSION: Y-90 microsphere radioembolisation is a safe method and may be helpful in treating patients with unresectable hepatocellular tumours. More favourable results were obtained in the patients treated using the more selective approach. AFP levels before and after treatment could predict survival rates.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Microesferas , Estudos Retrospectivos , Resultado do Tratamento , Radioisótopos de Ítrio/uso terapêutico
3.
Turk J Med Sci ; 49(6): 1640-1646, 2019 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-31655536

RESUMO

Background/aim: The Pipeline Flex Embolization Device (PED Flex) is a new updated version of the PED classic that incorporates a new delivery system to allow facilitation of stent deployment, resheathing, and removal of the capture coil. This study evaluated the PED Flex in terms of the technical aspects of the procedure and first-year follow-up results. Materials and methods: This retrospective study involved prospectively collected data from May 2015 to August 2017. The primary endpoint was technical aspects of the procedure, and the secondary endpoint was first-year follow-up results. Results: Forty-nine patients with 59 target intracranial aneurysms were enrolled. Patients' mean age was 52 years (range 21−71 years), and 31 (63.0%) were female. All aneurysms except for three were unruptured. The mean aneurysm diameter was 8 mm. Forty-seven patients with 56 aneurysms were successfully treated. Due to advancement, repositioning, and migration problems, 8 (13.1%) stents were not deployed and discharged. The total aneurysm occlusion rate was 77.0%. The mortality rate was 4.3%. Conclusion: Our experience shows that the applicability and safety of the renewed delivery system provided by PED Flex for improving device apposition and opening has been proven with one-year angiographic and clinical follow-up results.


Assuntos
Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Adulto , Idoso , Angiografia por Tomografia Computadorizada , Embolização Terapêutica/métodos , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
4.
Sisli Etfal Hastan Tip Bul ; 52(1): 13-18, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-32595365

RESUMO

OBJECTIVES: Percutaneous cholecystostomy (PC) for acute cholecystitis (AC) is frequently performed in high-risk surgical patients as an alternative treatment modality. However, debate remains over whether or not an interval cholecystectomy for these patients should be performed. The aim of this study was to investigate the outcomes of PC in high-risk surgical patients with AC. METHODS: Between September 2013 and June 2016, 27 of 952 patients with AC were treated with PC. The data collection included demographic variables, including comorbidities, the timing of the PC, the length of the hospital stay, the follow-up period, the complications related to PC, and readmission to hospital. RESULTS: There were 16 female and 11 male patients, with a mean age of 73±12.4 years (range: 49-97 years). Comorbid diseases included ischemic heart disease (n=6), diabetes mellitus (n=5), chronic obstructive pulmonary disease (n=6), and others (n=10). The mean timing of PC was 2.2±1.4 days (range: 1-3 days). The mean length of hospital stay was 9.6±2.1 days (range: 7-14 days), and the catheter was removed after the first month. The mean follow-up period after the PC catheter removal was 19.6±8.6 months (range: 10-38 months). Only 6 patients (22.2 %) were readmitted to the hospital. Cholecystectomy was performed in 4 cases, and 2 responded to medical treatment. CONCLUSION: Despite ongoing controversy about the management of AC in high-risk surgical patients, PC is an adequate and safely applicable procedure in this group of patients. However, an interval cholecystectomy should be considered in persistent cases, which account for a small percentage. Longer-term follow-up studies with a larger sample size are needed to support our results.

5.
Angiology ; 66(2): 174-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24554426

RESUMO

We evaluated whether the neutrophil-lymphocyte ratio (NLR) was associated with the presence, severity, and extent of coronary atherosclerotic plaques detected by computed tomography angiography (CTA). We studied 238 patients who underwent dual-source 64-slice CTA for the assessment of coronary artery disease. Coronary arteries were evaluated on 16-segment basis and critical plaque was described as luminal narrowing >50%. In regression analysis, being in the third NLR tertile increased the risk of coronary atherosclerosis (odds ratio [OR], 2.30; 95% confidence interval [CI], 1.15-4.43; P = .023). When the severity of coronary atherosclerosis was assessed, being in the third NLR tertile increased the risk of critical luminal stenosis (OR, 2.60; 95% CI, 1.19-5.69; P = .017). Although plaque morphology was not associated with NLR, the extent of coronary atherosclerosis was increased with higher NLR tertiles (P = .001). Our results suggest that a higher NLR may be a useful additional measure to assess cardiovascular risk in clinical practice.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Linfócitos , Tomografia Computadorizada Multidetectores , Neutrófilos , Placa Aterosclerótica , Adulto , Idoso , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/sangue , Estenose Coronária/diagnóstico por imagem , Estudos Transversais , Feminino , Humanos , Modelos Logísticos , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Fatores de Risco , Índice de Gravidade de Doença
6.
Iran J Radiol ; 10(3): 182-4, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24348609

RESUMO

BACKGROUND: Although liver biopsy is an easy procedure for hospitalized patients and outpatients, some complications may occur. OBJECTIVES: To evaluate the efficiency, complications, safety and clinicopathological utility of ultrasonographic-guided percutaneous liver biopsy in diffuse liver disease. PATIENTS AND METHODS: In our retrospective study, we evaluated ultrasound-assisted needle biopsies that were performed in outpatients from October 2006 to July 2010. The liver biopsies were performed following one-night fasting using the tru-cut biopsy gun (18-20 gauge) after marking the best seen and hypovascular part of the liver, distant enough from the adjacent organs. RESULTS: A total of 1018 patients were referred to our radiology department. Most of the patients had hepatitis B (60.6%). The biopsy specimens were recorded and sent to our pathology department for histopathological examination. CONCLUSION: According to the results of our series, percutaneous liver biopsy using the tru-cut biopsy gun guided by ultrasonography can be performed safely. We resolve that routine ultrasound of the puncture site is a quick, effective and safe procedure. The complication rate is very low. The US-assisted percutaneous liver biopsy should be used for all cases.

7.
Acad Radiol ; 20(4): 453-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23498986

RESUMO

RATIONALE AND OBJECTIVES: Diagnostic measures that can be used for sliding hiatal hernia are barium swallow radiography, endoscopy, manometry, and computed tomography. The aim of this study was to evaluate the diagnostic accuracy of transabdominal ultrasonography for sliding hiatal hernias. MATERIALS AND METHODS: This retrospective study was performed in the radiology department of a tertiary care center between May 2011 and May 2012. Twenty-one patients (10 females, 11 males) with sliding hiatal hernias and 41 controls (37 females, 4 males) were enrolled in this study. Esophageal hiatal diameters measured by ultrasonography and computerized tomography were compared. Correlation was tested via Pearson correlation analysis. RESULTS: The average age of patients and controls were 58.6 and 40.1, respectively. There was a statistically significant difference between esophageal hiatal diameters measured via ultrasonography in patients (31.7 mm) and controls (11.6 mm) (P < .001). Similarly, esophageal hiatal diameters measured via computed tomography in patients (31.4 mm) was statistically significantly higher than controls (11.5 mm) (P < .001). The average body mass index of patients (28.3) was higher than that of control group (P = .015). Ultrasonographic measurements were correlated well with tomographic results (P = .000, r = 0.995). CONCLUSION: Ultrasonography seems to be a valuable, safe, and practical alternative that avoids the side effects of contrast agents in the diagnosis of sliding hiatal hernias. Overall, we suggest that inclusion of ultrasound in the initial diagnostic steps for patients with sliding hiatal hernias may reduce the requirement for more expensive procedures.


Assuntos
Hérnia Hiatal/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...